| Fill Heights |
 |
|
| 2
2/3 x 1/2 STANDARD CMP FILL HEIGHT |
Height-of-Cover
Limits for Corrugated Steel Pipe
H20 or H25 LIVE LOAD 22/3 x 1/2 |
| Diameter
or Span, (in.) |
Minimum
Cover,
(in.) |
Maximum
Cover, (ft.) |
| Specified
Thickness, (in.) |
| 0.064 |
0.079 |
0.109 |
0.138 |
0.168 |
| 12 |
12 |
248 |
310 |
|
|
|
| 15 |
12 |
199 |
248 |
|
|
|
| 18 |
12 |
168 |
207 |
|
|
|
| 21 |
12 |
142 |
178 |
249 |
|
|
| |
|
|
|
|
|
|
| 24 |
12 |
124 |
155 |
218 |
|
|
| 30 |
12 |
99 |
124 |
174 |
|
|
| 36 |
12 |
83 |
103 |
145 |
186 |
|
| 42 |
12 |
71 |
88 |
124 |
160 |
195 |
| |
|
|
|
|
|
|
| 48 |
12 |
62 |
77 |
109 |
140 |
171 |
| 54 |
12 |
|
66 |
93 |
122 |
150 |
| 60 |
12 |
|
|
79 |
104 |
128 |
| 66 |
12 |
|
|
68 |
88 |
109 |
| |
|
|
|
|
|
|
| 72 |
12 |
|
|
|
75 |
93 |
| 78 |
12 |
|
|
|
|
79 |
| 84 |
12 |
|
|
|
|
66 |
|
|
| Deep
Core Corrugated Metal Pipe |
 |
|
Height-of-Cover
Limits for Corrugated Steel Pipe
H20 or H25 3 x 1 in. Corrugations |
| Diameter
or Span, (in.) |
Minimum
Cover, (in.) |
Maximum
Cover, (ft.) |
| Specified
Thickness, (in.) |
| 0.064 |
0.079 |
0.109 |
0.138 |
0.168 |
| 54 |
12 |
56 |
70 |
98 |
126 |
155 |
| 60 |
12 |
50 |
63 |
88 |
114 |
139 |
| 66 |
12 |
46 |
57 |
80 |
103 |
126 |
| 72 |
12 |
42 |
52 |
73 |
95 |
116 |
| 78 |
12 |
39 |
48 |
68 |
87 |
107 |
| 84 |
12 |
36 |
45 |
63 |
81 |
99 |
| 90 |
12 |
33 |
42 |
59 |
76 |
93 |
| 96 |
12 |
31 |
39 |
55 |
71 |
87 |
| 102 |
18 |
29 |
37 |
52 |
67 |
82 |
| 108 |
18 |
|
35 |
49 |
63 |
77 |
| 114 |
18 |
|
32 |
45 |
58 |
71 |
| 120 |
18 |
|
30 |
41 |
54 |
66 |
| 126 |
18 |
|
|
39 |
50 |
62 |
| 132 |
18 |
|
|
36 |
47 |
57 |
| 138 |
18 |
|
|
33 |
43 |
53 |
| 144 |
18 |
|
|
|
39 |
49 |
|
|
| Spiral
Rib |
 |
|
Height-of-Cover
Limits for Steel Spiral Rib Pipe
¾
x ¾ x 7½ in. and ¾ x 1 x
11½ in Configuration, H20 or H25 LIVE
LOAD |
| Diameter
or Span, inches |
Minimum
Cover,
inches |
Maximum
Depth of Cover Above Top of Pipe (Feet) |
| ¾ x
1 x 11½ in. Corrugation |
¾ x ¾ x
7½ Corrugation |
| 0.064 |
0.079 |
0.109 |
0.064 |
0.079 |
0.109 |
0.138 |
| 24 |
12 |
51 |
72 |
121 |
51 |
72 |
121 |
|
| 30 |
12 |
41 |
58 |
97 |
41 |
58 |
97 |
|
| 36 |
12 |
34 |
48 |
81 |
34 |
48 |
81 |
|
| 42 |
12 |
29 |
41 |
69 |
29 |
41 |
69 |
|
| 48 |
12 |
26 |
36 |
61 |
26 |
36 |
61 |
|
| 54 |
18 |
23 |
32 |
54 |
(23) |
32 |
54 |
|
| 60 |
18 |
(21) |
29 |
49 |
[21] |
29 |
49 |
73 |
| 66 |
18 |
[19] |
26 |
44 |
|
(26) |
44 |
65 |
| 72 |
18 |
|
(24) |
40 |
|
[24] |
40 |
59 |
| 78 |
24 |
|
[22] |
37 |
|
[22] |
(37) |
55 |
| 84 |
24 |
|
[21] |
(35) |
|
|
(35) |
52 |
| 90 |
24 |
|
|
(32) |
|
|
[32] |
47 |
| 96 |
24 |
|
|
[30] |
|
|
[30] |
44 |
| 102 |
30 |
|
|
[29] |
|
|
[29] |
43 |
| 108 |
30 |
|
|
[27] |
|
|
|
(41) |
|
|
| Maximum
Fill Heights for H2O Loads ¾
x 1 x 8½ in. Profile |
| Diameter
in inches |
Maximum
Fill heights, ft.
Spec. Thickness = 0.109 |
| 102 |
36 |
| 108 |
34 |
| 114 |
32 |
| 120 |
31 |
| 126 |
29 |
| 132 |
28 |
| 138 |
27 |
| 144 |
25 |
| Note
: Minimum
fill height is Diameter/4 |
|
|
| Trishield |
 |
|
TriShield
Height of Cover Table
Maximum
Cover (Feet) For Specified Thickness |
| Diameter
or Span |
Minimum
Cover |
Specified
Wall Thickness / Gauge |
| (inches) |
(inches) |
0.064"/16 |
0.079"/14 |
0.109"/12 |
| 24 |
12 |
72 |
100 |
167 |
| 30 |
12 |
57 |
80 |
133 |
| 36 |
12 |
48 |
67 |
111 |
| 42 |
12 |
41 |
57 |
95 |
| 48 |
12 |
36 |
50 |
83 |
| 54 |
18 |
(32) |
44 |
74 |
| 60 |
18 |
[29] |
40 |
67 |
| 66 |
18 |
[26] |
(36) |
61 |
| 72 |
18 |
** |
[33] |
56 |
| 78 |
24 |
|
[31] |
51 |
| 84 |
24 |
|
** |
(48) |
| 90 |
24 |
|
|
(44) |
| 96 |
24 |
|
|
[42] |
| 102 |
30 |
|
|
[37] |
| 108 |
|
|
|
** |
| Note : |
| |
1. |
Sizes indicated
in red are not currently available. |
| |
2. |
Fill heights are for H20
and H25 live loads. |
| |
3. |
TYPE I installations are
allowed unless otherwise shown. |
| |
4. |
( ) Requires a TYPE II or
TYPE III installation. |
| |
5. |
[ ] Requires a TYPE III
installation. |
|
|
|
| TOP |
Phone: 1-877-874-7443 | Fax: 949-650-0781 | Email: info@pcpipe.com